VIRGINIA KMP CORP -- BLAST-A-COIL, BAC201 -- 7930-00N086244
===================== Product Identification =====================
Product ID:BLAST-A-COIL, BAC201
MSDS Date:05/15/1996
FSC:7930
NIIN:00N086244
=== Responsible Party ===
Company Name:VIRGINIA KMP CORP
Address:4100 PLATINUM WAY
City:DALLAS
State:TX
ZIP:75237
Country:US
Info Phone Num:214-330-7731
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:DO738
=== Contractor Identification ===
Company Name:VIRGINIA K M P CORPORATION
Address:4100 PLATINUM WAY
Box:City:DALLAS
State:TX
ZIP:75237
Country:US
Phone:214-330-7731
CAGE:8J132
Company Name:VIRGINIA KMP CORP.
Address:4100 PLATINUM WAY
City:DALLAS
State:TX
ZIP:75237
Country:US
Phone:214-330-7731
CAGE:DO738
============= Composition/Information on Ingredients =============
Ingred Name:ETHYLENE, TRICHLORO-; (TRICHLOROETHYLENE) (SARA 313)
(CERCLA). LD50: (ORAL, RAT) 4.92 ML/KG.
CAS:79-01-6
RTECS #:KX4550000
OSHA PEL:100 PPM
ACGIH TLV:50 PPM; 100 STEL
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Ingred Name:FIRST AID PROC: IMMED MED ATTN. DO NOT GIVE ANYTHING BY
MOUTH TO UNCON PERSON. IF SPONTANEOUS VOMITING OCCURS, (ING 3)
RTECS #:9999999ZZ
Ingred Name:ING 2: KEEP HEAD BELOW HIPS.
RTECS #:9999999ZZ
Ingred Name:HNDLG/STOR PRECS: ELECTRICITY. STORE IN A COOL, DRY PLACE
AWAY FROM HEAT (<120F), IGNITION SOURCES, OXIDIZERS & (ING 5)
RTECS #:9999999ZZ
Ingred Name:ING 4: STRONG ACIDS.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:SEE INGREDIENT 1
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON MATLS HAVE PRDCED SENSIT
OF THE MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE A
SIMILAR EFFECT IN HUMANS. ADRENOMIMETICS (EG, EPINEPHRINE) MAY BE
CONTRA-INDICATED EXCEPT FOR LIFE- SUSTAINING USES IN HUMANS
ACUTELY/CHRONICALLY EXPOSED TO CHLOROCARBONS . INHAL: EXCESSIVE
INHAL (EFTS OF OVEREXP)
Explanation of Carcinogenicity:ETHYLENE, TRICHLORO-: IARC MONOGRAPHS,
VOL 63, PG 75, 1995:GROUP 2A. ANIMAL BLOOD & LIVER.
Effects of Overexposure:HLTH HAZ: OF VAPS CAN BE HARMFUL & MAY CAUSE
HDCH, DIZZ, ASPHY, ANESTH EFFECTS & POSS UNCON. EYE CONTACT: VAPS &
LIQS IRRITATING TO EYES. SKIN CONTACT: IRRITANT TO SKIN. INGEST:
POSS CHEM PNEUMIT IF A SPIRATED INTO LUNGS. NAUS. CHRONIC: (EFTS
DUE TO EXCESSIVE EXPOS TO RAW MATLS OF THIS MIXTURE) MAY CAUSE
LIVER (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL: REMOVE TO FRESH AIR. IF NOT BRTHG, APPLY ARTF RESP.
KEEP VICTIM WARM. SEEK MED ADVICE. EYES: FLUSH W/LG AMTS OF RUNNING
WATER FOR AT LEAST 15 MIN OCCASNLY LIFTING LOWER & UPPER EYELIDS.
SEEK ME D ADVICE. SKIN: WASH EXPOSED AREA W/SOAP & WATER. REMOVE
CONTAM CLTHG. SEEK MED ADVICE IF SYMPS DEVELOP. INGEST: GIVE WATER.
DO NOT INDUCE VOMIT. ASPIR INTO LUNGS MAY CAUSE CHEM PNEUM. SEEK
(ING 2)
===================== Fire Fighting Measures =====================
Extinguishing Media:USE CARBON DIOXIDE, ALCOHOL FOAM, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH APPROVED PRESSURE DEMAND SCBA AND
FULL PROTECTIVE EQUIPMENT . STAY UPWIND, KEEP ALL PERSONNEL AWAY.
COOL FIRE EXPOSED CONTAINERS WITH WATER.
Unusual Fire/Explosion Hazard:WARNING! PRODUCT UNDER PRESSURE, MAY
EXPLODE FROM EXCESSIVE HEAT. WATER MAY BE INEFTIVE TO FIGHT FIRE.
TOXIC GASES MAY BE PRDCED IN FIRE. HAZ COMBUST (SUPDAT)
================== Accidental Release Measures ==================
Spill Release Procedures:ISOLATE HAZ AREA. KEEP UNNEC & UNPROT PERS
AWAY. CLEAN UP SPILLS & LEAKS IMMED TO PVNT SOIL & WATER CONTAM.
LAND SPILL:ABSORB SPILL W/INERT, NON-COMBUST MATL THEN PLACE IN
CHEM WASTE CNTNR. WATER SPIL L:CNTN MATL. COLLECT & STORE IN CHEM
WASTE CNTNR.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:USE W/ADEQ VENT. AVOID SKIN/EYE
CONTACT & BREATHING VAPORS. DO NOT CUT, WELD, BRAZE, SOLDER, DRILL
OR EXPOSE TO HEAT, FLAME, SPARKS, STATIC (ING 4)
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE THE FORMATION OF HCL AND/OR PHOSGENE .
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF TLV EXCEEDED, NIOSH APPROVED RESPIRATOR FOR
ORGANIC VAPORS.
Ventilation:ADEQUATE VENTILATION TO CONTROL VAPOR ACCUMULATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EYE WASH & DELUGE SHOWER .
WEAR CHEMICAL IMPERVIOUS APRON TO PROTECT FROM SPLASHING.
Work Hygienic Practices:WASH CLOTHING BEFORE REUSE.
Supplemental Safety and Health
SPEC GRAV: CONCENTRATE ONLY:1.45. EVAP RATE: 2.6 CONCENTRATE ONLY
(N-BUTYL ACETATE=1). EXPLO HAZ: PRODS:SMOKE, FUMES, OXIDES OF
CARBON & SMALL AMTS OF FUMES OF PHOSGENE & CHLORIDES. EFTS OF
OVEREXP: A BNORMS, KIDNEY, SPLEEN, LUNG OR BRAIN DAMAGE, CARDIAC
ABNORMALITIES.
================== Physical/Chemical Properties ==================
Vapor Pres:85-100PSIG
Spec Gravity:SUPDAT
Evaporation Rate & Reference:SUPDAT
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR, COLORLESS SPRAY WITH LEMON CHLORINATED
SOLVENT ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
REACTIVE METALS, ALUMINUM, MAGNESIUM AND STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:AVOID EXCESSIVE HEAT, IGNITION SOURCES AND
FLAMES. ISOLATE FROM OXIDIZERS AND STRONG ACIDS.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
HYDROCHLORIC ACID, SMALL AMOUNTS OF PHOSGENE AND CHLORINE FUMES.
==================== Disposal Considerations ====================
Waste Disposal Methods:CLASSIFICATION OF WASTE REQUIRED BEFORE
DISPOSAL. FOLLOW ALL LOCAL, STATE AND FEDERAL REGULATIONS. AEROSOL
CANS WHEN VENTED TO ATMOSPHERE PRESSURE THROUGH NORMAL USE, POSE NO
DISPOSAL HAZARD.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.