DARWORTH CO -- POLYSEAMSEAL ALL PURPOSE ADHESIVE CAULK -- 8030-00N057437
=====================  Product Identification  =====================

Product ID:POLYSEAMSEAL ALL PURPOSE ADHESIVE CAULK
MSDS Date:01/03/1994
FSC:8030
NIIN:00N057437
=== Responsible Party ===
Company Name:DARWORTH CO
Address:3 MILL POND LANE
Box:639
City:SIMSBURG
State:CT
ZIP:06070
Country:US
Info Phone Num:203-843-1200
Emergency Phone Num:800-624-7767
CAGE:IO148
=== Contractor Identification ===
Company Name:DARWORTH CO
Address:TOWER LANE
Box:K
City:AVON
State:CT
ZIP:06001
Country:US
Phone:800-672-3499; 800-228-7103
CAGE:IO148
Company Name:DARWORTH INC
Address:TOWER LANE
Box:K
City:AVON
State:CT
ZIP:06001
Country:US
Phone:203-677-7721
CAGE:51405

=============  Composition/Information on Ingredients  =============

Ingred Name:PROPIONIC ACID, 2-METHYL-, MONOESTER
    W/2,2,4-TRIMETHYL-1,3-PENTANEDIOL;
    (2,2,4-TRIMETHYLPENTANEDIOL-1,3-MONOISOBUTYRATE)
CAS:25265-77-4
RTECS #:UF6000000
Fraction by Wt: 3-4%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:ACETIC ACID, BUTYL ESTER; (N-BUTYL ACETATE)  (CERCLA)
CAS:123-86-4
RTECS #:AF7350000
Fraction by Wt: 4-5%
OSHA PEL:150 PPM
ACGIH TLV:150 PPM;200 STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:1,2-PROPANEDIOL; (PROPYLENE GLYCOL)
CAS:57-55-6
RTECS #:TY2000000
Fraction by Wt: 2-3%
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:ING 2:EYE CONTACT CAUSES SEVERE
    IRRITATION. VAPORS MAY BE IRRITATING & CAUSE DIZZINESS, HEADACHE,
    NAUSEA, VOMITING & NARCOSIS. CHRONIC:OVEREXPOSURE TO THIS MATERIAL
    (OR ITS COMPONENTS) HAS APPAR ENTLY BEEN FOUND TO CAUSE FOLLOWING
    EFFECTS IN LAB ANIMALS: LIVER ABNORMALITIES, KIDNEY DAMAGE, LUNG
    (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:DAMAGE, BRAIN DAMAGE, BLOOD
    ABNORMALITIES. REPORTS HAVE ASSOCIATED REPEATED & PROLONGED
    OCCUPATIONAL OVEREXPOSURE TO SOLVENTS W/PERMANENT BRAIN & NERVOUS
    SYSTEM DAMAGE (INHALATION).
Medical Cond Aggravated by Exposure:PEOPLE W/PRE-EXISTING SKIN
    DISORDERS MAY BE MORE SUSCEPTIBLE TO EFTS OF THIS PROD. PEOPLE
    W/PRE-EXISTING RESP DISORDERS SUCH AS ASTHMA, MAY BE AGGRAVATED BY
    EXPOS TO THIS MATL.

=======================  First Aid Measures  =======================

First Aid:EYE:IMMED FLUSH W/LG QTYS OF WATER FOR AT LST 15 MINS. SEEK
    IMMED MED ATTN. SKIN:WASH W/SOAP & LG QTYS OF WATER & SEEK MED ATTN
    IF IRRIT PERSISTS. INHAL:IF VICTIM EXHIBITS RESP DISTRESS, REMOVE
    VICTIM  FROM CONTAM AREA. IF BRTHG STOPS, BEGIN ARTF RESP & SEEK
    IMMED MED ATTN. INGEST:INDUCE VOMIT IF VICTIM IS CONSCIOUS. SEEK
    IMMED MED ADVICE/ATTN.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:WATER, FOAM, CARBON DIOXIDE OR DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT . USE WATER TO COOL EXPOSED MATERIAL.
Unusual Fire/Explosion Hazard:KEEP WORK AREAS FREE OF HOT METAL
    SURFACES & OTHER SOURCES OF IGNITION.

==================  Accidental Release Measures  ==================

Spill Release Procedures:KEEP SOURCES OF IGNITION & HOT METAL SURFACES
    ISOLATED FROM SPILL. SPILLED MATERIAL MAY BE REMOVED W/INERT
    ABSORBENT & SHOVEL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:THE USE OF RESPIRATORY PROTECTION DEPENDS ON
    VAPOR CONCENTRATIONS. IF ABOVE THE TLV OR PEL, USE A NIOSH/MSHA
    APPROVED ORGANIC VAPOR RESPIRATOR.
Ventilation:LOC EXHST:REQD IF GEN VENT PROVES INADEQ TO MAINTAIN SAFE
    VAP CONCS. INDOORS:DO NOT USE IN CONFINED SPACE W/OUT (SUPDAT)
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:AVAILABILITY OF ANSI APPRVD EYE WASHES &
    SFTY SHOWERS IN WORK AREAS IS REC .IMPERMEABLE APRONS ARE
    ADVISED(SUPDAT)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HAZ DECOMP PROD:LOW MOLECULAR WT HYDROCARBONS MAY BE FORMED. VENT:ADEQ
    MECH VENT. MECH:USE MECH GEN ROOM/LOC VENT IF NEC TO MAINTAIN
    EMPLOYEE EXPOS BELOW PEL'S & TLV'S. OUTDOORS:MECH VENT OR NIOSH/MSH
    A APPRVD RESP PROT NOT NORMALLY REQD. EYE PROT:& FULL LENGTH
    FACESHIELD . OTHER PROT.EQUIP:TO PVNT SKIN CONTACT.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:212F,100C
Vapor Pres:15 @ 25C
Spec Gravity:1.25
Evaporation Rate & Reference:LESS THAN ETHER
Solubility in Water:MISCIBLE
Appearance and Odor:WHITE OR COLORED PASTE W/SWEET BANANA ODOR.
Percent Volatiles by Volume:45.5

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG OXIDIZING AGENTS.
Hazardous Decomposition Products:THERMAL DECOMP IN PRESENCE OF AIR MAY
    YIELD CARBON MONOXIDE &/OR CARBON DIOXIDE. UNDER SEV THERMAL
    DEGRADATION (SUPDAT)

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF PRODUCT I/A/W APPLICABLE LOCAL,
    COUNTY, STATE & FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.