DARWORTH CO -- POLYSEAMSEAL ALL PURPOSE ADHESIVE CAULK -- 8030-00N057437
===================== Product Identification ===================== Product ID:POLYSEAMSEAL ALL PURPOSE ADHESIVE CAULK MSDS Date:01/03/1994 FSC:8030 NIIN:00N057437 === Responsible Party === Company Name:DARWORTH CO Address:3 MILL POND LANE Box:639 City:SIMSBURG State:CT ZIP:06070 Country:US Info Phone Num:203-843-1200 Emergency Phone Num:800-624-7767 CAGE:IO148 === Contractor Identification === Company Name:DARWORTH CO Address:TOWER LANE Box:K City:AVON State:CT ZIP:06001 Country:US Phone:800-672-3499; 800-228-7103 CAGE:IO148 Company Name:DARWORTH INC Address:TOWER LANE Box:K City:AVON State:CT ZIP:06001 Country:US Phone:203-677-7721 CAGE:51405 ============= Composition/Information on Ingredients ============= Ingred Name:PROPIONIC ACID, 2-METHYL-, MONOESTER W/2,2,4-TRIMETHYL-1,3-PENTANEDIOL; (2,2,4-TRIMETHYLPENTANEDIOL-1,3-MONOISOBUTYRATE) CAS:25265-77-4 RTECS #:UF6000000 Fraction by Wt: 3-4% OSHA PEL:N/K ACGIH TLV:N/K Ingred Name:ACETIC ACID, BUTYL ESTER; (N-BUTYL ACETATE) (CERCLA) CAS:123-86-4 RTECS #:AF7350000 Fraction by Wt: 4-5% OSHA PEL:150 PPM ACGIH TLV:150 PPM;200 STEL EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS Ingred Name:1,2-PROPANEDIOL; (PROPYLENE GLYCOL) CAS:57-55-6 RTECS #:TY2000000 Fraction by Wt: 2-3% OSHA PEL:N/K ACGIH TLV:N/K ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:ACUTE:ING 2:EYE CONTACT CAUSES SEVERE IRRITATION. VAPORS MAY BE IRRITATING & CAUSE DIZZINESS, HEADACHE, NAUSEA, VOMITING & NARCOSIS. CHRONIC:OVEREXPOSURE TO THIS MATERIAL (OR ITS COMPONENTS) HAS APPAR ENTLY BEEN FOUND TO CAUSE FOLLOWING EFFECTS IN LAB ANIMALS: LIVER ABNORMALITIES, KIDNEY DAMAGE, LUNG (EFTS OF OVEREXP) Explanation of Carcinogenicity:NOT RELEVANT Effects of Overexposure:HLTH HAZ:DAMAGE, BRAIN DAMAGE, BLOOD ABNORMALITIES. REPORTS HAVE ASSOCIATED REPEATED & PROLONGED OCCUPATIONAL OVEREXPOSURE TO SOLVENTS W/PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE (INHALATION). Medical Cond Aggravated by Exposure:PEOPLE W/PRE-EXISTING SKIN DISORDERS MAY BE MORE SUSCEPTIBLE TO EFTS OF THIS PROD. PEOPLE W/PRE-EXISTING RESP DISORDERS SUCH AS ASTHMA, MAY BE AGGRAVATED BY EXPOS TO THIS MATL. ======================= First Aid Measures ======================= First Aid:EYE:IMMED FLUSH W/LG QTYS OF WATER FOR AT LST 15 MINS. SEEK IMMED MED ATTN. SKIN:WASH W/SOAP & LG QTYS OF WATER & SEEK MED ATTN IF IRRIT PERSISTS. INHAL:IF VICTIM EXHIBITS RESP DISTRESS, REMOVE VICTIM FROM CONTAM AREA. IF BRTHG STOPS, BEGIN ARTF RESP & SEEK IMMED MED ATTN. INGEST:INDUCE VOMIT IF VICTIM IS CONSCIOUS. SEEK IMMED MED ADVICE/ATTN. ===================== Fire Fighting Measures ===================== Extinguishing Media:WATER, FOAM, CARBON DIOXIDE OR DRY CHEMICAL. Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE EQUIPMENT . USE WATER TO COOL EXPOSED MATERIAL. Unusual Fire/Explosion Hazard:KEEP WORK AREAS FREE OF HOT METAL SURFACES & OTHER SOURCES OF IGNITION. ================== Accidental Release Measures ================== Spill Release Procedures:KEEP SOURCES OF IGNITION & HOT METAL SURFACES ISOLATED FROM SPILL. SPILLED MATERIAL MAY BE REMOVED W/INERT ABSORBENT & SHOVEL. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER. Other Precautions:NONE SPECIFIED BY MANUFACTURER. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:THE USE OF RESPIRATORY PROTECTION DEPENDS ON VAPOR CONCENTRATIONS. IF ABOVE THE TLV OR PEL, USE A NIOSH/MSHA APPROVED ORGANIC VAPOR RESPIRATOR. Ventilation:LOC EXHST:REQD IF GEN VENT PROVES INADEQ TO MAINTAIN SAFE VAP CONCS. INDOORS:DO NOT USE IN CONFINED SPACE W/OUT (SUPDAT) Protective Gloves:RUBBER GLOVES. Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT) Other Protective Equipment:AVAILABILITY OF ANSI APPRVD EYE WASHES & SFTY SHOWERS IN WORK AREAS IS REC .IMPERMEABLE APRONS ARE ADVISED(SUPDAT) Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. Supplemental Safety and Health HAZ DECOMP PROD:LOW MOLECULAR WT HYDROCARBONS MAY BE FORMED. VENT:ADEQ MECH VENT. MECH:USE MECH GEN ROOM/LOC VENT IF NEC TO MAINTAIN EMPLOYEE EXPOS BELOW PEL'S & TLV'S. OUTDOORS:MECH VENT OR NIOSH/MSH A APPRVD RESP PROT NOT NORMALLY REQD. EYE PROT:& FULL LENGTH FACESHIELD . OTHER PROT.EQUIP:TO PVNT SKIN CONTACT. ================== Physical/Chemical Properties ================== Boiling Pt:B.P. Text:212F,100C Vapor Pres:15 @ 25C Spec Gravity:1.25 Evaporation Rate & Reference:LESS THAN ETHER Solubility in Water:MISCIBLE Appearance and Odor:WHITE OR COLORED PASTE W/SWEET BANANA ODOR. Percent Volatiles by Volume:45.5 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES AVOID CONTACT W/STRONG OXIDIZING AGENTS. Hazardous Decomposition Products:THERMAL DECOMP IN PRESENCE OF AIR MAY YIELD CARBON MONOXIDE &/OR CARBON DIOXIDE. UNDER SEV THERMAL DEGRADATION (SUPDAT) ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE OF PRODUCT I/A/W APPLICABLE LOCAL, COUNTY, STATE & FEDERAL REGULATIONS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.